Hochschule/AG: Architekt ![]() ![]() ![]() ![]() ![]() Beitrag Datum: 23.08.2010 Uhrzeit: 23:10 ID: 40520 | Social Bookmarks: Hmm, do you really need an attic of that height? If not, just cut off the curtain wall so that it matches the top of your angle profile (variant A). That's exactly where the water proofing may end (in Germany, you have to go 15 cm above the general water proofing level). Is the front sandwich panel an asset in the building's elevation? If not, omit the panel by raising the glazing to the top of the lowered attic. |
![]() | ||||
Thema | Autor | Architektur-Themenbereiche | Antworten | Letzter Beitrag |
Suche ein Buch (kauf), Standard-Detail-Sammlung | tegeltiger | Suche | 1 | 01.07.2009 15:39 |
suche detail, übergang glasfassade - geneigtes dach | s-r-boom | Konstruktion & Technik | 3 | 01.06.2007 18:32 |
Suche Detail 2004|9 sakrale Bauten | juli | Suche | 0 | 26.02.2007 23:47 |